Transmation calibrator cross reference

Transmation calibrator cross reference

Transmation calibrators have been around since the late 1960s. The first milliamp calibrators had analog meter movements and were housed in extruded aluminum enclosures that were large and heavy. The Transmation 1040 became a standard for instrument technicians even though the digits on the LCD display were the size of a digital watch display. The Transmation 1040, and the Transmation 1080 combined a 4 to 20 milliamp, 10 to 50 milliamp, and voltage calibrator into one device. These were discontinued in 2001.

Other discontinued models include the Transmation 1060, 1061, 1062, 1064P and 1065-MTC thermocouple calibrators, Transmation 1074 and CheckMate 500 RTD calibrators, Transmation 1021, 1022, 1027, 1028, 1030, 1143, 1180 and CheckMate 100 milliamp calibrators, 1188 & CheckMate 100 multifunction calibrator and the Transmation 1070 & 1174 frequency calibrators. Many of these models are so old they that replacement parts no longer exist and are no longer repairable. Or for the models that can be repaired, the cost of repair often exceeds the cost of a replacement PIE calibrator!

When you check the accuracy of some of these obsolete calibrators you will find that they are no longer accurate enough to calibrate modern process instruments. Why risk using a piece of test equipment designed in the 1970s or 1980s to calibrate a state-of-the-art control system.

Transmation calibrators also used miniature banana jacks that required non-standard test leads and many of them contained expensive rechargeable battery packs. PIE Calibrators use standard, replaceable “AA” and 9V batteries and have standard banana jacks and come with standard test leads. Find hidden problems in 4 to 20 milliamp loops, broken wires from RTD sensors and excessive loop loads with troubleshooting features found only on PIE calibrators. Upgrade your Transmation process calibrator with a PIE Evolutionary Calibrator and see how much easier it is to use and how much time you save on each calibration.


Transmation Calibrator upgrade to PIE

Type Transmation Model Upgrade to PIE Model
Multifunction Transmation CheckMate 1000 820
Multifunction Transmation 1188 830
Thermocouple Transmation Checkmate 400 322-1
Thermocouple Transmation 1064P, 1060, 1061 & 1062 322-1
Thermocouple Transmation 1065-MTC 422
RTD Transmation 1074 311
RTD Transmation CheckMate 500 311
RTD Transmation 1173 311
Milliamp Transmation CheckMate 100, 1021, 1022, 1027, 1028, 1030 334
Milliamp Transmation 1143 434
Milliamp Transmation 43 434
Milliamp (4-20) & Voltage Transmation 1040, Transmation 1045 Transmation 1080 or Transmation 1180 532
Milliamp (10-50) & Voltage Transmation 1048 535
Milliamp (10-50) & Voltage Transmation 1040 or Transmation 1080 535
Voltage Transmation CheckMate 200 235
Frequency Transmation 1070, Transmation 1173 or Transmation CheckMate 300 541